Size of the tub and quantity of EL-300
|
|
The dimensions of the steel tub should be approximately 20” longer than
the overall length of the electrode and pre-set nipple and level of EL-300
should be approximately 4” higher than the top of surface of the electrode.
Using a tub larger than suggested will result in the waste of and a higher
cost of EL-300.
The following table shows the required amount of EL-300 to be kept as well
as the dimensions of the tubs to be used for various size electrodes. |
|
Diameter |
Length of Electrode(mm)
Pole + Nipple = Total |
Dimension of Tub(mm)
Width x Depth x Length |
Required EL-300
(kgs) |
inch |
mm |
8 |
200 |
1500 + 89 = 1589 |
300 x 450 x 1900 |
140 |
14 |
350 |
1800 + 153 =1953 |
500 x 650 x 2200 |
420 |
16 |
400 |
1800 + 170 = 1970 |
550 x 700 x 2250 |
500 |
18 |
460 |
1800 + 170 = 1970 |
600 x 800 x 2300 |
600 |
20 |
510 |
1800 + 178 = 1978 |
700 x 900 x 2400 |
900 |
20 |
510 |
2100 + 178 = 2278 |
700 x 900 x 2650 |
980 |
24 |
610 |
2400 + 186 = 2586 |
800 x 1000 x 3000 |
1370 |
28 |
710 |
2800 + 280 = 3080 |
900 x 1100 x 3500 |
1940 |
Table 1) Dimension of Tub and Required EL-300 (per one charge) |